Celebrating 75 Years of Independence

Contact Us
Close
  • Home
  • Services
  • Case Studies
  • Products
  • More
Analyze Your Site
WMKY-2000 TYPE GAS DETECTOR
WMKY-2000 TYPE GAS DETECTOR

WMKY-2000 TYPE GAS DETECTOR

ITEM CONTECTS
MEASURING RANGE PPM %VOL %LEL
DETECTION MODE DIFFUSION TYPE
MEASUREMENT ACCURACY +-5%F.S
DISPLAY MODE LED DIGITAL DISPLAY
REPEATABILITY +-2%F.S
RESPONSE TIME 20~180 SECONDS, DEPENDS ON GAS RANGE
EXPLOSION PROOF GRADE EXDLLCT6
OUTPUT SIGNAL (3-WIRE, 4-20MA) (4-WIRE, RS485)
EFFECT ≤5W
WORKING POWER SUPPLY 24VDC +-20%
SERVICE TEMPERATURE -20 ~ +75C
DETECTION GAS FLAMMABLE OR TOXIC GAS

WMKY-2000A/B/C TYPE GAS ALARM CONTROLLER

ITEM CONCENTS
CONTROLLER TYPE (4-20mA: 8 CHANNELS) (RS485: 16 CHANNELS, 64 CHANNELS)
HOST POWER CONSUMPTION LESS THAN 50W
USE ENVIRONMENT -10 ~70 C (INDOOR)
VOLTAGE RANGE 220VAC+- 15% (50HZ)
LINKAGE PATH FORECAST AND ALARM
SIGNAL TRANSMISSION DISTANCE LESS THAN 1500 M
INSTALLATION MODE HANGING WALL TYPE
EXPLOSION PROOF GRADE EXDIICT6
OUTLINE SIZE 320MM* 240MM* 100MM
SIGNAL OUTPUT (3-WIRE,4-20MADC) (4-WIRE,485 DIGITAL SIGNAL)

PRODUCT CHARACTERISTICS

  1. 4-20mA, RS485, SWITCHING QUANTITY AND OTHER SIGNAL OUTPUT; MEET DIFFERENT USES

  2. FLAMEPROOF SHELL DESIGN, SAFE AND RELIABLE, HIGH PROTECTION LEVEL

  3. LONG - TERM STABILITY, SPIRITUAL ELEGANCE AND AUTOMATIC ADJUSTMENT, STABLE WORK

  4. EASY TO OPEN WIRING, EASY TO INSTALL AND DEBUG

  5. HIGH RELIABILITY; CAN REACT TO A VARIETY OF GAS MEDIA.

  6. CAN BE EQUIPPED WITH LED DISPLAY, INTUITIVE AND CLEAR

  7. IT CAN ALSO ADD ON-SITE SOUND AND LIGHT ALARM TO ACHIEVE DUAL ALARM FUNCTION.

    THE USE OF ALARM CONTROLLER

    THE MULTI- POINT MONITORING AND ALARM CONTROLLER IS USED TO DETECT THE CONTENT OF COMBUSTIBLE GAS OR LIQUID VAPOR WITHIN THE LOWER LIMIT OF EXPLOSION IN AIR. IT CAN CARRY MULTIPLE DETECTION PROBES AND CENTRALIZE MULTI-POINT CONTROL AT THE SAME TIME.

    THE PRINCIPAL OF ALARM CONTROLLER

    THE SYSTEM USES MICROPROCESSOR AS CONTROL UNIT, WHICH HAS HIGH SENSITIVITY AND RESPONSE SPEED. WHEN THE CONCENTRATION OF FLAMMABLE GASES IN THE ENVIRONMENT REACHES OR EXCEEDS THE PRESET ALARM VALUE, THE CONTROLLER IMMEDIATELY SENDS OUT SOUND AND LIGHT ALARM, AND DRIVES EXHAUST AIR OR OTHER PERIPHERAL ACTIONS TO PREVENT EXPLOSION AND FIRE ACCIDENTS, SO AS TO PROTECT LIFE.